Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Chinese Journal of Laboratory Medicine ; (12): 643-645, 2016.
Article in Chinese | WPRIM | ID: wpr-498586

ABSTRACT

Objective To investigate the problems during using, standard and quality management of the POCT glucose meters in hospital, to analyze the solutions, and to provide reference data for improving the test level of POCT in hospital.Methods The amount, brand and application of portable glucose meters in the hospital were obtained by 3 rounds of surveillance from May to July in 2013.All of those glucose meters were taken part in external quality assessment of Clinical Laboratory Center of National Health and Family Planning Commission.The test results of those glucose meters were compared with that of automatic biochemical analyzer, the comparison results were then analyzed.Results The POCT glucose meters possessed 5 brands in our hospital, and the amount and type of glucose meters in some clinical departments were often changed.When 4 brands which were detected as quality control samples by ministry of health, the accuracy of detection results of 3 concentration of brand Ⅲ were substandard, the CV% of two levels were 11.9%and 10.1%respectively, the remaining 3 brands were in line with the requirements.The qualified percentages of 3 times of comparison were 85.0%, 92.0%and 97.4%.Conclusions The hospital should select the brand of portable glucose meters reasonably, correct use of glucose meters, and it is very necessary to build indoor and interstitial quality evaluation system, at the same time, suggesting the hospital to establish the POCT quality management team, to carry out the instrument comparison periodically, so to guarantee the accurate, reliable results of POCT in hospital.

2.
Chinese Journal of Clinical Oncology ; (24): 46-50, 2014.
Article in Chinese | WPRIM | ID: wpr-440197

ABSTRACT

Nano-biosensors have elicited considerable scientific interest in various research areas, including nanotechnology, bio-technology, microelectronics, and analytical techniques. The development of nanomaterials and nanotechnology has produced nano-bio-sensors with increasing potential applications in disease diagnosis. Prostate cancer is a malignant tumor that seriously threatens the health human males worldwide. Detecting the low-abundance biomarkers of prostate cancer is critical for its early diagnosis, treatment monitoring, and evaluation of its postsurgical recurrence. This review focuses on the research progress in nano-biosensing technology and its application in the detection of prostate cancer biomarkers.

3.
Military Medical Sciences ; (12): 365-367,370, 2014.
Article in Chinese | WPRIM | ID: wpr-599247

ABSTRACT

Objective To investigate the flora distribution and drug resistance status in the Affiliated Hospital of Academy of Military Medical Sciences so as to provide experimental data for clinical doctors to use antibiotics more efficiently.Methods The clinical data of pathogenic bacterial infections over nearly one year in our hospital were retro -spectively analyzed .Results There were 3815 strains of pathogenic bacteria isolated from the sample .The percentage of Gram-positive strains was 36.4%while that of Gram-negative bacteria was 63.6%.The most common bacteria were Esche-richia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa and Staphylococcus epidermidis.In terms of drug tolerance , Enterobacteriaceae remained highily sensitive to carbapenems .The total resistance rate was 2%-5%.The resistance rate of A.baumannii to meropenem and imipenem was 60%.There were still a few pan-drug resistant strains among K.pneumoniae,A.baumannii and P.aeruginosa,but there were no drug resistant strains to vancomycin , tige-cycline and linezolid in Staphylococcus.The resistance rate of Enterococcus faecium to vancomycin was 9%.The bacteria were distributed predominantly in ICU ,Department of Hematology and Department of Oncology .The samples were mainly composed of phlegm specimens .Conclusion The high distribution in the three departments mentioned above is largely re-lated to the diseases being treated .The specimens from the lower respiratory tract show more types of bacteria that are mostly drug-resistant, and the isolating rate of vancomycin resistant Enterococcus and carbapenems resistant K.pneumoniat is com-paratively high .

4.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 299-302, 2012.
Article in English | WPRIM | ID: wpr-635413

ABSTRACT

Many researchers employed mammalian expression system to artificially express cannabinoid receptors, but immunoblot data that directly prove efficient protein expression can hardly be seen in related research reports. In present study, we demonstrated cannabinoid receptor protein was not able to be properly expressed with routine mammalian expression system. This inefficient expression was rescued by endowing an exogenous signal peptide ahead of cannabinoid receptor peptide. In addition, the artificially synthesized cannabinoid receptor was found to aggregate under routine sample denaturing temperatures (i.e., [Symbol: see text]95°C), forming a large molecular weight band when analyzed by immuno-blotting. Only denaturing temperatures [Symbol: see text]75°C yielded a clear band at the predicted molecular weight. Collectively, we showed that efficient mammalian expression of cannabinoid receptors need a signal peptide sequence, and described the requirement for a low sample denaturing temperature in immuno-blot analysis. These findings provide very useful information for efficient mammalian expression and immuno-blotting of membrane receptors.

5.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 626-627, 2003.
Article in Chinese | WPRIM | ID: wpr-988033

ABSTRACT

@# ObjectiveTo explore clinic features of large cerebral infarction and the relationship between infarcted area and prognosis.MethodsClinic materials such as dangerous factors, onset, course, treatment and prognosis, brain CT changes and internal carotid artery ultrasonic examinations of 68 patients with large cerebral infarction were analyzed retrospectively.ResultsThere were 28 cases caused by cerebral embolism, and 40 cases caused by cerebral thrombosis. 6 cases got recovery, and 34 cases, progress, and 11 cases,no progress, and 17 cases, death. ConclusionThe infarcted area was significantly related to prognosis (P<0.05). Internal carotid artery frequently occurring atheromas and senile non-valve atrial fibrillation were major embolic origins for large cerebral infarction.11 out of the 17 deaths could be attributed to brain herniation and secondary infection. The early abnormal brain CT showed that the rate of mortality was 62.5%, and the rate of mid-line dislocation was 42.9%. Either of them indicated that prognosis was bad.

6.
Medical Journal of Chinese People's Liberation Army ; (12)1983.
Article in Chinese | WPRIM | ID: wpr-561432

ABSTRACT

Objective To study the radiation effects on the serum concentration of urea nitrogen (BUN), creatinine (Cre), ?2-microglobulin (?2-MG) and uric acid (UA), and to evaluate the injuries to renal function induced by a 60 Co irradiation accident in Shandong province. Methods The concentrations of urea nitrogen, serum creatinine and serum uric acid were determined by enzymatic methods. The concentrations of serum ?2-microglobulin were determined by the immunoturbidity methods using HITACHI 7170s automatic biochemical analyzer. Results The serum concentrations of BUN and Cre of 2 patients increased significantly after irradiation, and the serum concentration of UA in the two cases elevated too after irradiation, but didn't reach the normal value. The serum concentrations of ?2-microglobulin also increased significantly after irradiation. In case A which received 20~25Gy irradiation, the concentrations of serum BUN, creatinine and ?2-microglobulin increased to 41.63mmol/L, 364?mol/L and 9.2mg/L, respectively. In case B which received 9~15Gy irradiation, the concentration of serum BUN, creatinine and ?2-microglobulin increased to 52.2mmol/L, 199?mol/L and 11.3mg/L, respectively. There seemed a dosage-dependent effect on the BUN, Cre and ?2-microglobulin concentration. Conclusion 60 Co may irradiate the tissues of kidney directly, and irradiate the cells of other tissues and organs, lead to necrosis and degenerations accordingly on the tissues of kidneys and other organs. In the process of necrosis and degenerations, a large amount of metabolic products was released which is poisonous to the kidney. The present results showed the concentrations increased of all the four renal serum markers mentioned above. It is supposed that the renal cells might be damaged by the Cobalt ? ray irradiation.

SELECTION OF CITATIONS
SEARCH DETAIL